Export limit exceeded: 386839 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (4322 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-8530 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 5.9 Medium |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS. | ||||
| CVE-2024-12054 | 2026-04-15 | 5.4 Medium | ||
| ZF Roll Stability Support Plus (RSSPlus) is vulnerable to an authentication bypass vulnerability targeting deterministic RSSPlus SecurityAccess service seeds, which may allow an attacker to remotely (proximal/adjacent with RF equipment or via pivot from J2497 telematics devices) call diagnostic functions intended for workshop or repair scenarios. This can impact system availability, potentially degrading performance or erasing software, however the vehicle remains in a safe vehicle state. | ||||
| CVE-2012-10062 | 2 Apache Friends, Apachefriends | 2 Xampp, Xampp | 2026-04-15 | N/A |
| A vulnerability in XAMPP, developed by Apache Friends, version 1.7.3's default WebDAV configuration allows remote authenticated attackers to upload and execute arbitrary PHP code. The WebDAV service, accessible via /webdav/, accepts HTTP PUT requests using default credentials. This permits attackers to upload a malicious PHP payload and trigger its execution via a subsequent GET request, resulting in remote code execution on the server. | ||||
| CVE-2025-41703 | 1 Phoenix Contact | 4 Quint4-ups/24dc/24dc/10/eip, Quint4-ups/24dc/24dc/20/eip, Quint4-ups/24dc/24dc/40/eip and 1 more | 2026-04-15 | 7.5 High |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. | ||||
| CVE-2025-41689 | 2026-04-15 | 7.5 High | ||
| An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data. | ||||
| CVE-2025-41716 | 1 Wago | 1 Solution Builder | 2026-04-15 | 5.3 Medium |
| The web application allows an unauthenticated remote attacker to learn information about existing user accounts with their corresponding role due to missing authentication for critical function. | ||||
| CVE-2025-41715 | 2026-04-15 | 9.8 Critical | ||
| The database for the web application is exposed without authentication, allowing an unauthenticated remote attacker to gain unauthorized access and potentially compromise it. | ||||
| CVE-2025-41655 | 2026-04-15 | 7.5 High | ||
| An unauthenticated remote attacker can access a URL which causes the device to reboot. | ||||
| CVE-2025-41654 | 2026-04-15 | 8.2 High | ||
| An unauthenticated remote attacker can access information about running processes via the SNMP protocol. The amount of returned data can trigger a reboot by the watchdog. | ||||
| CVE-2025-41651 | 2026-04-15 | 9.8 Critical | ||
| Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leading to full system compromise. | ||||
| CVE-2025-40817 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 6.5 Medium |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. | ||||
| CVE-2025-40816 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 7.6 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. | ||||
| CVE-2025-40771 | 1 Siemens | 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more | 2026-04-15 | 9.8 Critical |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. | ||||
| CVE-2024-12757 | 2026-04-15 | 8.6 High | ||
| Nedap Librix Ecoreader is missing authentication for critical functions that could allow an unauthenticated attacker to potentially execute malicious code. | ||||
| CVE-2025-36535 | 1 Automationdirect | 1 Mb Gateway | 2026-04-15 | 10 Critical |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. | ||||
| CVE-2024-12802 | 2026-04-15 | 9.1 Critical | ||
| SSL-VPN MFA Bypass in SonicWALL SSL-VPN can arise in specific cases due to the separate handling of UPN (User Principal Name) and SAM (Security Account Manager) account names when integrated with Microsoft Active Directory, allowing MFA to be configured independently for each login method and potentially enabling attackers to bypass MFA by exploiting the alternative account name. | ||||
| CVE-2024-12838 | 2026-04-15 | 8.8 High | ||
| The passwordless login mechanism in CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability, allowing remote attackers with regular privileges to send a crafted request to switch to the identity of any user, including administrators. | ||||
| CVE-2016-15045 | 2026-04-15 | N/A | ||
| A local privilege escalation vulnerability exists in lastore-daemon, the system package manager daemon used in Deepin Linux (developed by Wuhan Deepin Technology Co., Ltd.). In versions 0.9.53-1 (Deepin 15.5) and 0.9.66-1 (Deepin 15.7), the D-Bus configuration permits any user in the sudo group to invoke the InstallPackage method without password authentication. By default, the first user created on Deepin is in the sudo group. An attacker with shell access can craft a .deb package containing a malicious post-install script and use dbus-send to install it via lastore-daemon, resulting in arbitrary code execution as root. | ||||
| CVE-2016-15046 | 1 Hanwha-security | 1 Smart Security Manager | 2026-04-15 | N/A |
| A client-side remote code execution vulnerability exists in Hanwha Techwin Smart Security Manager (SSM) versions 1.32 and 1.4, due to improper restrictions on the PUT method exposed by the bundled Apache ActiveMQ instance (running on port 8161). An attacker can exploit this flaw through a Cross-Origin Resource Sharing (CORS) bypass combined with JavaScript-triggered file uploads to the web server, ultimately resulting in arbitrary code execution with SYSTEM privileges. This vulnerability bypasses the server-side mitigations introduced in ZDI-15-156 and ZDI-16-481 by shifting the exploitation to the client-side. This product is now referred to as Hanwha Wisenet SSM and it is unknown if current versions are affected. | ||||
| CVE-2025-34073 | 2026-04-15 | N/A | ||
| An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process. | ||||