Search Results (8845 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-17422 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 9.3 Critical
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to execute arbitrary code due to a buffer overflow.
CVE-2026-17195 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 6.5 Medium
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to cause a denial of service due to an out-of-bounds write.
CVE-2026-17170 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 7.5 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to improper validation of an allocation size.
CVE-2026-17168 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 8.5 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote authenticated attacker to execute arbitrary code due to a stack-based buffer overflow.
CVE-2026-17165 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 7.5 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to a NULL pointer dereference.
CVE-2026-17159 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 7.5 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to an integer overflow.
CVE-2026-17160 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 9.8 Critical
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to execute arbitrary code due to an integer overflow during size computation.
CVE-2026-17042 1 Ibm 21 Power Hardware Management Console \(7063-cr2\), Power Hardware Management Console \(7063-cr2\) Firmware, Power System Ac922 \(8335-gth\) and 18 more 2026-08-25 7.3 High
IBM Power Systems Firmware FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware NVRAM parsing. An attacker with root access to a guest partition on an OpenPOWER system can write a specially crafted NVRAM image, causing the host firmware boot stage to crash with possible memory corruption. This condition persists until operator intervention — clearing NVRAM via the service processor — to restore normal operation. This vulnerability only affects OpenPOWER systems; systems running PowerVM are not affected. Successful exploitation results in an integrity and availability impact to the managed system.
CVE-2026-17468 1 Ibm 1 Documentation Offline 2026-08-25 5.3 Medium
IBM Documentation Offline 1.0.0 through 1.4.1 could allow a remote attacker to forge valid session tokens due to the use of a hardcoded cryptographic key.
CVE-2026-17473 1 Ibm 1 Documentation Offline 2026-08-25 7.5 High
IBM Documentation Offline 1.0.0 through 1.4.1 could allow a remote attacker to read arbitrary files due to improper limitation of a pathname to a restricted directory.
CVE-2026-17063 1 Ibm 39 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 36 more 2026-08-25 7.9 High
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact.
CVE-2026-16922 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to execute arbitrary code due to a time-of-check to time-of-use (TOCTOU) race condition.
CVE-2026-16923 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to improper privilege management.
CVE-2026-16924 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7.5 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to an improper calculation of a memory offset during IPsec decapsulation.
CVE-2026-16925 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7.1 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to achieve privilege escalation due to improper authorization.
CVE-2026-16927 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7.3 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain root privileges due to a time-of-check to time-of-use (TOCTOU) race condition.
CVE-2026-16928 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7.5 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to a heap-based buffer overflow.
CVE-2026-16932 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 8.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to execute arbitrary commands due to improper validation of the ODMDIR environment variable.
CVE-2026-16930 1 Ibm 39 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 36 more 2026-08-24 8.2 High
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can execute arbitrary code on the host system, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
CVE-2026-16989 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7.1 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to improper resolution of symbolic links.