| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics
Solution is only in scope of
this vulnerability when
installed on a NUC server. BD Synapsys™
Informatics Solution installed
on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is
not in scope. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel. |
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |
| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. |
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory.
For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.
Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared.
Newer firmware versions might be vulnerable as well. |
| The TELNET service of AdTran NetVanta 3120 18.01.01.00.E devices is enabled by default, and has default credentials for a root-level account. |
| iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients. |
| Use of Default Cryptographic Key in the hardware for some Intel(R) Pentium(R) Processor Silver Series, Intel(R) Celeron(R) Processor J Series, Intel(R) Celeron(R) Processor N Series may allow an escalation of privilege. Hardware reverse engineer adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via physical access when attack requirements are present with special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (high), integrity (high) and availability (none) impacts. |
| Ilevia EVE X1 Server firmware versions ≤ 4.7.18.0.eden contain a use of default credentials vulnerability that allows an unauthenticated attacker to obtain remote access. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet. |
| Use of Default Credentials, Hard-coded Credentials vulnerability in C2SGlobalSettings.dll in
Milner ImageDirector Capture on Windows allows decryption of document archive files using credentials decrypted with hard-coded application encryption key.
This issue affects ImageDirector Capture: from 7.0.9.0 before 7.6.3.25808. |
| Multiple services of the DUT as well as different scopes of the same service reuse the same credentials. |
| PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use default, shared credentials for the administrative web interface. |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. |
| Airship AI Acropolis includes a default administrative account that uses the same credentials on every installation. Instances of Airship AI that do not change this account password are vulnerable to a remote attacker logging in and gaining the privileges of this account. Fixed in 10.2.35, 11.0.21, and 11.1.9. |
| The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges. |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device. |
| Default credentials on the Web Interface of Evolution Controller 2.x allows anyone to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the password. There is no warning or prompt to ask the user to change the default password. |
| A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider. |