Export limit exceeded: 390071 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (97910 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2019-6845 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2024-11-21 | 7.5 High |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. | ||||
| CVE-2019-6839 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-11-21 | 8.8 High |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file. | ||||
| CVE-2019-6836 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file. | ||||
| CVE-2019-6834 | 1 Schneider-electric | 1 Software Update | 2024-11-21 | 7.3 High |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0) | ||||
| CVE-2019-6832 | 1 Schneider-electric | 4 Lss100100, Lss100200, Spacelynk Firmware and 1 more | 2024-11-21 | 8.3 High |
| A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication. | ||||
| CVE-2019-6831 | 1 Schneider-electric | 2 Bmxnor0200h, Bmxnor0200h Firmware | 2024-11-21 | 8.6 High |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP. | ||||
| CVE-2019-6828 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus. | ||||
| CVE-2019-6827 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. | ||||
| CVE-2019-6826 | 1 Schneider-electric | 1 Somachine Hvac | 2024-11-21 | 7.8 High |
| A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product. | ||||
| CVE-2019-6825 | 1 Schneider-electric | 1 Proclima | 2024-11-21 | 7.8 High |
| A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0. | ||||
| CVE-2019-6822 | 1 Schneider-electric | 1 Zelio Soft 2 | 2024-11-21 | 7.8 High |
| A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file. | ||||
| CVE-2019-6813 | 1 Schneider-electric | 4 Bmxnor0200h, Bmxnor0200h Firmware, Modicon M340 and 1 more | 2024-11-21 | 7.5 High |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device. | ||||
| CVE-2019-6812 | 1 Schneider-electric | 2 Bmx-nor-0200h, Bmx-nor-0200h Firmware | 2024-11-21 | 7.2 High |
| A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol. | ||||
| CVE-2019-6811 | 1 Schneider-electric | 4 Modicon Quantum 140noe77101, Modicon Quantum 140noe77101 Firmware, Modicon Quantum 140noe77111 and 1 more | 2024-11-21 | 7.5 High |
| An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover. | ||||
| CVE-2019-6810 | 1 Schneider-electric | 2 Bmxnor0200h, Bmxnor0200h Firmware | 2024-11-21 | 8.8 High |
| CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol. | ||||
| CVE-2019-6809 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller. | ||||
| CVE-2019-6807 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | ||||
| CVE-2019-6806 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. | ||||
| CVE-2019-6793 | 1 Gitlab | 1 Gitlab | 2024-11-21 | 7.0 High |
| An issue was discovered in GitLab Enterprise Edition before 11.5.8, 11.6.x before 11.6.6, and 11.7.x before 11.7.1. The Jira integration feature is vulnerable to an unauthenticated blind SSRF issue. | ||||
| CVE-2019-6788 | 1 Gitlab | 1 Gitlab | 2024-11-21 | 7.5 High |
| An issue was discovered in GitLab Community and Enterprise Edition before 11.5.8, 11.6.x before 11.6.6, and 11.7.x before 11.7.1. It allows Information Disclosure (issue 3 of 6). For installations using GitHub or Bitbucket OAuth integrations, it is possible to use a covert redirect to obtain the user OAuth token for those services. | ||||