Export limit exceeded: 425989 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (95443 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-25267 1 Ilias 1 Ilias 2024-11-21 5.4 Medium
An XSS issue exists in the question-pool file-upload preview feature in ILIAS 6.4.
CVE-2020-25256 1 Hyland 1 Onbase 2024-11-21 9.1 Critical
An issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. PKI certificates have a private key that is the same across different customers' installations.
CVE-2020-25236 1 Siemens 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware 2024-11-21 5.5 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.
CVE-2020-25231 1 Siemens 3 Logo\! 8 Bm, Logo\! 8 Bm Firmware, Logo\! Soft Comfort 2024-11-21 5.5 Medium
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program files.
CVE-2020-25229 1 Siemens 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware 2024-11-21 7.5 High
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any affected device if using prepared messages that were generated for another device.
CVE-2020-25226 1 Siemens 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more 2024-11-21 9.8 Critical
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
CVE-2020-25217 1 Grandstream 14 Grp2612, Grp2612 Firmware, Grp2612p and 11 more 2024-11-21 7.2 High
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allows Command Injection as root in its administrative web interface.
CVE-2020-25212 5 Canonical, Debian, Linux and 2 more 10 Ubuntu Linux, Debian Linux, Linux Kernel and 7 more 2024-11-21 7.0 High
A TOCTOU mismatch in the NFS client code in the Linux kernel before 5.8.3 could be used by local attackers to corrupt memory or possibly have unspecified other impact because a size check is in fs/nfs/nfs4proc.c instead of fs/nfs/nfs4xdr.c, aka CID-b4487b935452.
CVE-2020-25206 1 Mimosa 6 B5, B5 Firmware, B5c and 3 more 2024-11-21 7.2 High
The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 allows authenticated command injection in the Throughput, WANStats, PhyStats, and QosStats API classes. An attacker with access to a web console account may execute operating system commands on affected devices by sending crafted POST requests to the affected endpoints (/core/api/calls/Throughput.php, /core/api/calls/WANStats.php, /core/api/calls/PhyStats.php, /core/api/calls/QosStats.php). This results in the complete takeover of the vulnerable device. This vulnerability does not occur in the older 1.5.x firmware versions.
CVE-2020-25205 1 Mimosa 6 B5, B5 Firmware, B5c and 3 more 2024-11-21 6.1 Medium
The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device's filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message presented to unauthenticated users who visit the login page for the web console. This vulnerability does not occur in the older 1.5.x firmware versions.
CVE-2020-25199 1 We-con 1 Levistudiou 2024-11-21 7.8 High
A heap-based buffer overflow vulnerability exists within the WECON LeviStudioU Release Build 2019-09-21 and prior when processing project files. Opening a specially crafted project file could allow an attacker to exploit and execute code under the privileges of the application.
CVE-2020-25191 1 Ni 2 Compactrio, Compactrio Firmware 2024-11-21 7.5 High
Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely.
CVE-2020-25177 1 We-con 1 Plc Editor 2024-11-21 8.8 High
WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution.
CVE-2020-25173 1 Reolink 14 Rlc-410, Rlc-410 Firmware, Rlc-422 and 11 more 2024-11-21 7.8 High
An attacker with local network access can obtain a fixed cryptography key which may allow for further compromise of Reolink P2P cameras outside of local network access
CVE-2020-25171 1 Fujielectric 1 V-server 2024-11-21 7.8 High
The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
CVE-2020-25161 1 Advantech 1 Webaccess\/scada 2024-11-21 8.8 High
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
CVE-2020-25159 1 Rtautomation 2 499es Ethernet\/ip Adaptor, 499es Ethernet\/ip Adaptor Firmware 2024-11-21 9.8 Critical
499ES EtherNet/IP (ENIP) Adaptor Source Code is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.
CVE-2020-25148 1 Observium 1 Observium 2024-11-21 6.1 Medium
An issue was discovered in Observium Professional, Enterprise & Community 20.8.10631. It is vulnerable to Cross-Site Scripting (XSS) due to the fact that it is possible to inject and store malicious JavaScript code within it. this can occur via /iftype/type= because of pages/iftype.inc.php.
CVE-2020-25146 1 Observium 1 Observium 2024-11-21 6.1 Medium
An issue was discovered in Observium Professional, Enterprise & Community 20.8.10631. It is vulnerable to Cross-Site Scripting (XSS) due to the fact that it is possible to inject and store malicious JavaScript code within it. This can occur via la_id to the /syslog_rules URI for edit_syslog_rule.
CVE-2020-25141 1 Observium 1 Observium 2024-11-21 6.1 Medium
An issue was discovered in Observium Professional, Enterprise & Community 20.8.10631. It is vulnerable to Cross-Site Scripting (XSS) due to the fact that it is possible to inject and store malicious JavaScript code within it. This can occur via a /device/device=140/tab=wifi/view= URI.