| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device. |
| Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct access to the app’s filesystem. |
| Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information. |
| next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems. |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |
| CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure
of data when network traffic is being sniffed by an attacker. |
| iMonitor EAM 9.6394 transmits communication between the EAM client agent and the EAM server, as well as between the EAM monitor management software and the server, in plaintext without authentication or encryption. An attacker with network access can intercept sensitive information (such as credentials, keylogger data, and personally identifiable information) and tamper with traffic. This allows both unauthorized disclosure and modification of data, including issuing arbitrary commands to client agents. |
| Ambiguous wording in the web interface of the ctrlX OS setup mechanism could lead the user to believe that the backup file is encrypted when a password is set. However, only the private key - if available in the backup - is encrypted, while the backup file itself remains unencrypted. |
| Valmet DNA user passwords in plain text. This practice poses a security risk as attackers who gain access to local project data can read the passwords. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| Cleartext Storage of Sensitive Information vulnerability in OpenText™ Vertica allows Retrieve Embedded Sensitive Data.
The vulnerability could read Vertica agent plaintext apikey.This issue affects Vertica versions: 23.X, 24.X, 25.X. |
| A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles. |
| CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to send communications to the update API in plaintext, allowing attackers to access sensitive information via a man-in-the-middle attack. |
| ibm.ibm_zhmc is an Ansible collection for the IBM Z HMC. The Ansible collection "ibm.ibm_zhmc" writes password-like properties in clear text into its log file and into the output returned by some of its Ansible module in the following cases: 1. The 'boot_ftp_password' and 'ssc_master_pw' properties are passed as input to the zhmc_partition Ansible module. 2. The 'ssc_master_pw' and 'zaware_master_pw' properties are passed as input to the zhmc_lpar Ansible module. 3. The 'password' property is passed as input to the zhmc_user Ansible module (just in log file, not in module output). 4. The 'bind_password' property is passed as input to the zhmc_ldap_server_definition Ansible module. These properties appear in the module output only when they were specified in the module input and when creating or updating the corresponding resources. They do not appear in the output when retrieving facts for the corresponding resources. These properties appear in the log file only when the "log_file" module input parameter is used. By default, no log file is created. This issue has been fixed in ibm.ibm_zhmc version 1.9.3. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| EWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |