Search Results (320 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-41313 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact"
CVE-2022-41312 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"
CVE-2022-41311 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text"
CVE-2016-8721 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 9.1 Critical
An exploitable OS Command Injection vulnerability exists in the web application 'ping' functionality of Moxa AWK-3131A Wireless Access Points running firmware 1.1. Specially crafted web form input can cause an OS Command Injection resulting in complete compromise of the vulnerable device. An attacker can exploit this vulnerability remotely.
CVE-2016-8720 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 4.3 Medium
An exploitable HTTP Header Injection vulnerability exists in the Web Application functionality of the Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted HTTP request can inject a payload in the bkpath parameter which will be copied in to Location header of the HTTP response.
CVE-2016-9333 1 Moxa 1 Softcms 2025-04-20 N/A
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION).
CVE-2016-8719 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 6.1 Medium
An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Specially crafted input, in multiple parameters, can cause a malicious scripts to be executed by a victim.
CVE-2016-8718 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 8.8 High
An exploitable Cross-Site Request Forgery vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted form can trick a client into making an unintentional request to the web server which will be treated as an authentic request.
CVE-2016-9346 1 Moxa 6 Miineport E1, Miineport E1 Firmware, Miineport E2 and 3 more 2025-04-20 N/A
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted.
CVE-2016-9356 1 Moxa 1 Dacenter 2025-04-20 N/A
An issue was discovered in Moxa DACenter Versions 1.4 and older. The application may suffer from an unquoted search path issue.
CVE-2017-7457 1 Moxa 1 Mx-aopc Server 2025-04-20 N/A
XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure.
CVE-2016-8716 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 7.5 High
An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. The Change Password functionality of the Web Application transmits the password in cleartext. An attacker capable of intercepting this traffic is able to obtain valid credentials.
CVE-2017-7915 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
CVE-2016-8712 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 8.1 High
An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds.
CVE-2017-13698 1 Moxa 2 Eds-g512e, Eds-g512e Firmware 2025-04-20 N/A
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded.
CVE-2016-8379 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 8.1 High
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.
CVE-2017-13701 1 Moxa 2 Eds-g512e, Eds-g512e Firmware 2025-04-20 N/A
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method.
CVE-2017-13700 1 Moxa 2 Eds-g512e, Eds-g512e Firmware 2025-04-20 N/A
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface.
CVE-2017-7455 1 Moxa 1 Mxview 2025-04-20 N/A
Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control.
CVE-2016-8372 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 8.1 High
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.