Search Results (1522 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-34694 1 Lnbits 1 Lnbits 2026-04-15 8.1 High
LNbits is a Lightning wallet and accounts system. Paying invoices in Eclair that do not get settled within the internal timeout (about 30s) lead to a payment being considered failed, even though it may still be in flight. This vulnerability can lead to a total loss of funds for the node backend. This vulnerability is fixed in 0.12.6.
CVE-2024-36440 1 Swissphone 1 Dical-red 2026-04-15 6.8 Medium
An issue was discovered on Swissphone DiCal-RED 4009 devices. An attacker with access to the file /etc/deviceconfig may recover the administrative device password via password-cracking methods, because unsalted MD5 is used.
CVE-2025-1718 2026-04-15 6.5 Medium
An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management.
CVE-2025-12387 1 Pix-link 1 Lv-wr21q 2026-04-15 N/A
A vulnerability in the Pix-Link LV-WR21Q router's language module allows remote attackers to trigger a denial of service (DoS) by sending a specially crafted HTTP POST request containing non-existing language parameter. This renders the server unable to serve correct lang.js file, which causes administrator panel to not work, resulting in DoS until the language settings is reverted to a correct value. The Denial of Service affects only the administrator panel and does not affect other router functionalities. The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version V108_108 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.
CVE-2025-9998 1 Arcinfo 1 Pcvue 2026-04-15 N/A
The sequence of packets received by a Networking server are not correctly checked. An attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.
CVE-2025-10205 1 Abb 1 Flxeon 2026-04-15 8.8 High
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions
CVE-2024-51744 2026-04-15 3.1 Low
golang-jwt is a Go implementation of JSON Web Tokens. Unclear documentation of the error behavior in `ParseWithClaims` can lead to situation where users are potentially not checking errors in the way they should be. Especially, if a token is both expired and invalid, the errors returned by `ParseWithClaims` return both error codes. If users only check for the `jwt.ErrTokenExpired ` using `error.Is`, they will ignore the embedded `jwt.ErrTokenSignatureInvalid` and thus potentially accept invalid tokens. A fix has been back-ported with the error handling logic from the `v5` branch to the `v4` branch. In this logic, the `ParseWithClaims` function will immediately return in "dangerous" situations (e.g., an invalid signature), limiting the combined errors only to situations where the signature is valid, but further validation failed (e.g., if the signature is valid, but is expired AND has the wrong audience). This fix is part of the 4.5.1 release. We are aware that this changes the behaviour of an established function and is not 100 % backwards compatible, so updating to 4.5.1 might break your code. In case you cannot update to 4.5.0, please make sure that you are properly checking for all errors ("dangerous" ones first), so that you are not running in the case detailed above.
CVE-2024-34360 2026-04-15 8.2 High
go-spacemesh is a Go implementation of the Spacemesh protocol full node. Nodes can publish activations transactions (ATXs) which reference the incorrect previous ATX of the Smesher that created the ATX. ATXs are expected to form a single chain from the newest to the first ATX ever published by an identity. Allowing Smeshers to reference an earlier (but not the latest) ATX as previous breaks this protocol rule and can serve as an attack vector where Nodes are rewarded for holding their PoST data for less than one epoch but still being eligible for rewards. This vulnerability is fixed in go-spacemesh 1.5.2-hotfix1 and Spacemesh API 1.37.1.
CVE-2025-43864 2026-04-15 7.5 High
React Router is a router for React. Starting in version 7.2.0 and prior to version 7.5.2, it is possible to force an application to switch to SPA mode by adding a header to the request. If the application uses SSR and is forced to switch to SPA, this causes an error that completely corrupts the page. If a cache system is in place, this allows the response containing the error to be cached, resulting in a cache poisoning that strongly impacts the availability of the application. This issue has been patched in version 7.5.2.
CVE-2025-54811 1 Openplcproject 2 Openplc V3, Openplc V3 Firmware 2026-04-15 7.1 High
OpenPLC_V3 has a vulnerability in the enipThread function that occurs due to the lack of a return value. This leads to a crash when the server loop ends and execution hits an illegal ud2 instruction. This issue can be triggered remotely without authentication by starting the same server multiple times or if the server exits unexpectedly. The vulnerability allows an attacker to cause a Denial of Service (DoS) against the PLC runtime, stopping any PC started remotely without authentication. This results in the PLC process crashing and halting all automation or control logic managed by OpenPLC.
CVE-2024-37284 2026-04-15 5.5 Medium
Improper handling of alternate encoding occurs when Elastic Defend on Windows systems attempts to scan a file or process encoded as a multibyte character. This leads to an uncaught exception causing Elastic Defend to crash which in turn will prevent it from quarantining the file and/or killing the process.
CVE-2024-38355 2026-04-15 7.3 High
Socket.IO is an open source, real-time, bidirectional, event-based, communication framework. A specially crafted Socket.IO packet can trigger an uncaught exception on the Socket.IO server, thus killing the Node.js process. This issue is fixed by commit `15af22fc22` which has been included in `socket.io@4.6.2` (released in May 2023). The fix was backported in the 2.x branch as well with commit `d30630ba10`. Users are advised to upgrade. Users unable to upgrade may attach a listener for the "error" event to catch these errors.
CVE-2025-61668 1 Plone 1 Volto 2026-04-15 N/A
Volto is a ReactJS-based frontend for the Plone Content Management System. Versions 16.34.0 and below, 17.0.0 through 17.22.1, 18.0.0 through 18.27.1, and 19.0.0-alpha.1 through 19.0.0-alpha.5, an anonymous user could cause the NodeJS server part of Volto to quit with an error when visiting a specific URL. This issue is fixed in versions 16.34.1, 17.22.2, 18.27.2 and 19.0.0-alpha.6.
CVE-2024-27457 2026-04-15 2.5 Low
Improper check for unusual or exceptional conditions in Intel(R) TDX Module firmware before version 1.5.06 may allow a privileged user to potentially enable information disclosure via local access.
CVE-2025-20070 1 Intel 1 Intel Optane Pmem Management Software 2026-04-15 6.7 Medium
Improper conditions check for the Intel(R) Optane(TM) PMem management software before versions CR_MGMT_02.00.00.4052, CR_MGMT_03.00.00.0538 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable [cvss_threat_loss_factor]. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-53638 2026-04-15 N/A
Solady is software that provides Solidity snippets with APIs. Starting in version 0.0.125 and prior to version 0.1.24, when an account is deployed via a proxy, using regular Solidity to call its initialization function may result in a silent failure, if the initialization function does not return a `bool` or some other return data. This is because regular Solidity uses `extcodesize(proxy)` to decide if call succeeds. This is insufficient in the case when the proxy points to an empty implementation. Users should upgrade to Solady v0.1.24 or later to receive a patch. Deploy any affected implementations and their factories on new EVM chains as soon as possible.
CVE-2024-52504 1 Siemens 1 Siprotec 4 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
CVE-2024-10945 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 7.3 High
A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation.
CVE-2025-41222 2026-04-15 5.3 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). Affected devices do not properly handle malformed TLS handshake messages. This could allow an attacker with network access to the webserver to cause a denial of service resulting in the web server and the device to crash.
CVE-2025-41241 1 Vmware 4 Cloud Foundation, Telco Cloud Infrastructure, Telco Cloud Platform and 1 more 2026-04-15 4.4 Medium
VMware vCenter contains a denial-of-service vulnerability. A malicious actor who is authenticated through vCenter and has permission to perform API calls for guest OS customisation may trigger this vulnerability to create a denial-of-service condition.