Search Results (22486 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-44678 1 Gigastone 1 Travel Router R101 Firmware 2026-04-15 8 High
Gigastone TR1 Travel Router R101 v1.0.2 is vulnerable to Command Injection. This allows an authenticated attacker to execute arbitrary commands on the device by sending a crafted HTTP request to the ssid parameter in the request.
CVE-2024-45251 1 Elsight 1 Halo Firmware 2026-04-15 9.8 Critical
Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-45252 1 Elsight 1 Halo Firmware 2026-04-15 9.8 Critical
Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44072 1 Buffalo Inc 18 Wex 1166dhp, Wex 1166dhp2, Wex 1166dhps and 15 more 2026-04-15 5.7 Medium
OS command injection vulnerability exists in BUFFALO wireless LAN routers and wireless LAN repeaters. If a user logs in to the management page and sends a specially crafted request to the affected product from the product's specific management page, an arbitrary OS command may be executed.
CVE-2024-45288 1 Freebsd 1 Freebsd 2026-04-15 8.4 High
A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2025-62713 1 Kottster 1 Kottster 2026-04-15 N/A
Kottster is a self hosted Node.js admin panel. From versions 3.2.0 to before 3.3.2, Kottster contains a pre-authentication remote code execution (RCE) vulnerability when running in development mode. This affects development mode only, production deployments were never affected. This issue has been fixed in version 3.3.2.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-61553 1 Bitvisor 1 Bitvisor 2026-04-15 8.2 High
An out-of-bounds write in VirtIO network device emulation in BitVisor from commit 108df6 (2020-05-20) to commit 480907 (2025-07-06) allows local attackers to cause a denial of service (host hypervisor crash) via a crafted PCI configuration space access. Given it's a heap overflow in a privileged hypervisor context, exploitation may enable arbitrary code execution or guest-to-host privilege escalation.
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-60017 1 Unitree 4 B2, G1, Go2 and 1 more 2026-04-15 8.2 High
Unitree Go2, G1, H1, and B2 devices through 2025-09-20 allow root OS command injection via the hostapd_restart.sh wifi_ssid or wifi_pass parameter (within restart_wifi_ap and restart_wifi_sta).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-59844 2 Microsoft, Sonarsource 2 Windows, Sonarqube Scanner 2026-04-15 N/A
SonarQube Server and Cloud is a static analysis solution for continuous code quality and security inspection. A command injection vulnerability exists in SonarQube GitHub Action in version 4.0.0 to before version 6.0.0 when workflows pass user-controlled input to the args parameter on Windows runners without proper validation. This vulnerability bypasses a previous security fix and allows arbitrary command execution, potentially leading to exposure of sensitive environment variables and compromise of the runner environment. The vulnerability has been fixed in version 6.0.0. Users should upgrade to this version or later.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-59733 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.5 Medium
When decoding an OpenEXR file that uses DWAA or DWAB compression, there's an implicit assumption that all image channels have the same pixel type (and size), and that if there are four channels, the first four are "B", "G", "R" and "A". The channel parsing code can be found in decode_header. The buffer td->uncompressed_data is allocated in decode_block based on the xsize, ysize and computed current_channel_offset. The function dwa_uncompress then assumes at [5] that if there are 4 channels, these are "B", "G", "R" and "A", and in the calculations at [6] and [7] that all channels are of the same type, which matches the type of the main color channels. If we set the main color channels to a 4-byte type and add duplicate or unknown channels of the 2-byte EXR_HALF type, then the addition at [7] will increment the pointer by 4-bytes * xsize * nb_channels, which will exceed the allocated buffer. We recommend upgrading to version 8.0 or beyond.
CVE-2025-59731 1 Ffmpeg 1 Ffmpeg 2026-04-15 N/A
When decoding an OpenEXR file that uses DWAA or DWAB compression, the specified raw length of run-length-encoded data is not checked when using it to calculate the output data. We read rle_raw_size from the input file at [0], we decompress and decode into the buffer td->rle_raw_data of size rle_raw_size at [1], and then at [2] we will access entries in this buffer up to (td->xsize - 1) * (td->ysize - 1) + rle_raw_size / 2, which may exceed rle_raw_size. We recommend upgrading to version 8.0 or beyond.
CVE-2025-59730 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.5 Medium
When decoding a frame for a SANM file (ANIM v0 variant), the decoded data can be larger than the buffer allocated for it. Frames encoded with codec 48 can specify their resolution (width x height). A buffer of appropriate size is allocated depending on the resolution. This codec can encode the frame contents using a run-length encoding algorithm. There are no checks that the decoded frame fits in the allocated buffer, leading to a heap-buffer-overflow. process_frame_obj initializes the buffers based on the frame resolution: We recommend upgrading to version 8.0 or beyond.