| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A Prototype Pollution issue in byondreal accessor <= 1.0.0 allows an attacker to execute arbitrary code via @byondreal/accessor/index. |
| The Runtime components of messageformat package for Node.js before 3.0.2 contain a prototype pollution vulnerability. Due to insufficient validation of nested message keys during the processing of message data, an attacker can manipulate the prototype chain of JavaScript objects by providing specially crafted input. This can result in the injection of arbitrary properties into the Object.prototype, potentially leading to denial of service conditions or unexpected application behavior. The vulnerability allows attackers to alter the prototype of base objects, impacting all subsequent object instances throughout the application's lifecycle. |
| Rollbar.js offers error tracking and logging from Javascript to Rollbar. In versions before 2.26.5 and from 3.0.0-alpha1 to before 3.0.0-beta5, there is a prototype pollution vulnerability in merge(). If application code calls rollbar.configure() with untrusted input, prototype pollution is possible. This issue has been fixed in versions 2.26.5 and 3.0.0-beta5. A workaround involves ensuring that values passed to rollbar.configure() do not contain untrusted input. |
| The latest version of utils-extend (1.0.8) is vulnerable to Prototype Pollution through the entry function(s) lib.extend. An attacker can supply a payload with Object.prototype setter to introduce or modify properties within the global prototype chain, causing denial of service (DoS) a the minimum consequence. |
| Parse Javascript SDK provides access to the powerful Parse Server backend from your JavaScript app. Prior to 7.0.0, injection of malicious payload allows attacker to remotely execute arbitrary code. ParseObject.fromJSON, ParseObject.pin, ParseObject.registerSubclass, ObjectStateMutations (internal), and encode/decode (internal) are affected. This vulnerability is fixed in 7.0.0. |
| Prototype pollution vulnerability in apidoc-core versions 0.2.0 and all subsequent versions allows remote attackers to modify JavaScript object prototypes via malformed data structures, including the “define” property processed by the application, potentially leading to denial of service or unintended behavior in applications relying on the integrity of prototype chains. This affects the preProcess() function in api_group.js, api_param_title.js, api_use.js, and api_permission.js worker modules. |
| Versions of the package expand-object from 0.0.0 are vulnerable to Prototype Pollution in the expand() function in index.js. This function expands the given string into an object and allows a nested property to be set without checking the provided keys for sensitive properties like __proto__. |
| jrburke requirejs v2.3.6 was discovered to contain a prototype pollution via the function s.contexts._.configure. This vulnerability allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via injecting arbitrary properties. |
| tRPC allows users to build and consume fully typesafe APIs without schemas or code generation. Starting in version 10.27.0 and prior to versions 10.45.3 and 11.8.0, a A prototype pollution vulnerability exists in `@trpc/server`'s `formDataToObject` function, which is used by the Next.js App Router adapter. An attacker can pollute `Object.prototype` by submitting specially crafted FormData field names, potentially leading to authorization bypass, denial of service, or other security impacts. Note that this vulnerability is only present when using `experimental_caller` / `experimental_nextAppDirCaller`. Versions 10.45.3 and 11.8.0 fix the issue. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. |
| A binding to an unrestricted IP address vulnerability was discovered in Productivity Suite software version v4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and read, write, or delete arbitrary files and folders on the target machine |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. |
| Radashi is a TypeScript utility toolkit. Prior to version 12.5.1, the set function within the Radashi library is vulnerable to prototype pollution. If an attacker can control parts of the path argument to the set function, they could potentially modify the prototype of all objects in the JavaScript runtime, leading to unexpected behavior, denial of service, or even remote code execution in some specific scenarios. This issue has been patched in version 12.5.1. A workaround for this issue involves sanitizing the path argument provided to the set function to ensure that no part of the path string is __proto__, prototype, or constructor. |
| Vue I18n is the internationalization plugin for Vue.js. @intlify/message-resolver and @intlify/vue-i18n-core are vulnerable to Prototype Pollution through the entry function: handleFlatJson. An attacker can supply a payload with Object.prototype setter to introduce or modify properties within the global prototype chain, causing denial of service (DoS) a the minimum consequence. Moreover, the consequences of this vulnerability can escalate to other injection-based attacks, depending on how the library integrates within the application. For instance, if the polluted property propagates to sensitive Node.js APIs (e.g., exec, eval), it could enable an attacker to execute arbitrary commands within the application's context. |
| Versions of the package mysql2 before 3.9.8 are vulnerable to Prototype Pollution due to improper user input sanitization passed to fields and tables when using nestTables. |
| A new feature to prevent Firmware downgrades was recently added to some Lexmark products. A method to
override this downgrade protection has been identified. |
| LangSmith Client SDKs provide SDK's for interacting with the LangSmith platform. Prior to 0.5.18, the LangSmith JavaScript/TypeScript SDK (langsmith) contains an incomplete prototype pollution fix in its internally vendored lodash set() utility. The baseAssignValue() function only guards against the __proto__ key, but fails to prevent traversal via constructor.prototype. This allows an attacker who controls keys in data processed by the createAnonymizer() API to pollute Object.prototype, affecting all objects in the Node.js process. This vulnerability is fixed in 0.5.18. |
| The Your Journey theme for WordPress is vulnerable to Reflected Cross-Site Scripting via prototype pollution in versions up to, and including, 1.9.8 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link. |
| The nsc theme for WordPress is vulnerable to Reflected Cross-Site Scripting via prototype pollution in versions up to, and including, 1.0 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link. |
| The Winters theme for WordPress is vulnerable to Reflected Cross-Site Scripting via prototype pollution in versions up to, and including, 1.4.3 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link. |