| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. |
| Improper access restrictions in HCL BigFix Remote Control Server WebUI (versions 10.1.0.0248 and lower) allow non-admin users to view unauthorized information on certain web pages. |
| Rasa Pro is a framework for building scalable, dynamic conversational AI assistants that integrate large language models (LLMs). A vulnerability has been identified in Rasa Pro where voice connectors in Rasa Pro do not properly implement authentication even when a token is configured in the credentials.yml file. This could allow an attacker to submit voice data to the Rasa Pro assistant from an unauthenticated source. This issue has been patched for audiocodes, audiocodes_stream, and genesys connectors in versions 3.9.20, 3.10.19, 3.11.7 and 3.12.6. |
| Uniweb/SoliPACS WebServer developed by EBM Technologies has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access a specific page to obtain user group names. |
| Simofa is a tool to help automate static website building and deployment. Prior to version 0.2.7, due to a design mistake in the RouteLoader class, some API routes may be publicly accessible when they should require authentication. This vulnerability has been patched in v0.2.7. |
| A flaw has been found in Magnetism Studios Endurance up to 3.3.0 on macOS. This affects the function loadModuleNamed:WithReply of the file /Applications/Endurance.app/Contents/Library/LaunchServices/com.MagnetismStudios.endurance.helper of the component NSXPC Interface. Executing manipulation can lead to missing authentication. The attack needs to be launched locally. The exploit has been published and may be used. |
| Traq versions 2.0 through 2.3 contain a remote code execution vulnerability in the admincp/common.php script. The flawed authorization logic fails to halt execution after a failed access check, allowing unauthenticated users to reach admin-only functionality. This can be exploited via plugins.php to inject and execute arbitrary PHP code. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |
| An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates. |
| An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced. |
| An unauthenticated user with management network access can get and
modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20)
configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP
ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration
and execute some commands (e.g., system reboot). |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| In the Airoha Bluetooth audio SDK, there is a possible permission bypass that allows access critical data of RACE protocol through Bluetooth LE GATT service. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| A flaw was found in Eclipse Che che-machine-exec. This vulnerability allows unauthenticated remote arbitrary command execution and secret exfiltration (SSH keys, tokens, etc.) from other users' Developer Workspace containers, via an unauthenticated JSON-RPC / websocket API exposed on TCP port 3333. |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| Sensitive information disclosure due to missing authentication. The following products are affected: Acronis True Image (macOS) before build 41725, Acronis True Image (Windows) before build 41736, Acronis True Image OEM (macOS) before build 42571, Acronis True Image OEM (Windows) before build 42575. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in Tenda TDSEE App up to 1.7.12. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /app/ConfirmSmsCode of the component Password Reset Confirmation Code Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.15 is able to address this issue. It is recommended to upgrade the affected component. |