| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission. |
| ** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data. |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |
| DuraComm SPM-500 DP-10iN-100-MU
transmits sensitive data without encryption over a channel that could be intercepted by attackers. |
| IPMI credentials may be captured in XCC audit log entries when the account username length is 16 characters. |
| Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL. |
| Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls (PA-7500, PA-5400, PA-5400f, PA-3400, PA-1600, PA-1400, and PA-400 Series) leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec.
This issue does not affect Cloud NGFWs, Prisma® Access instances, or PAN-OS VM-Series firewalls.
NOTE: The AES-128-CCM encryption algorithm is not recommended for use. |
| Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding. |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream.
The credentials are being sent when a user decides to change his password in router's portal. |
| A flaw was found in Event-Driven Automation (EDA) in Ansible Automation Platform (AAP), which lacks encryption of sensitive information. An attacker with network access could exploit this vulnerability by sniffing the plaintext data transmitted between the EDA and AAP. An attacker with system access could exploit this vulnerability by reading the plaintext data stored in EDA and AAP databases. |
| Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| Ecovacs Deebot T10 1.7.2 transmits Wi-Fi credentials in cleartext during the pairing process. |
| In TARGIT Decision Suite 23.2.15007.0 before Autumn 2023, the session token is part of the URL and may be sent in a cleartext HTTP session. |
| Let's Encrypt client and ACME library written in Go (Lego). In versions 4.25.1 and below, the github.com/go-acme/lego/v4/acme/api package (thus the lego library and the lego cli as well) don't enforce HTTPS when talking to CAs as an ACME client. Unlike the http-01 challenge which solves an ACME challenge over unencrypted HTTP, the ACME protocol requires HTTPS when a client communicates with the CA to performs ACME functions. However, the library fails to enforce HTTPS both in the original discover URL (configured by the library user) and in the subsequent addresses returned by the CAs in the directory and order objects. If users input HTTP URLs or CAs misconfigure endpoints, protocol operations occur over HTTP instead of HTTPS. This compromises privacy by exposing request/response details like account and request identifiers to network attackers. This was fixed in version 4.25.2. |