| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| PingID Windows Login prior to 2.8 does not authenticate communication with a local Java service used to capture security key requests. An attacker with the ability to execute code on the target machine maybe able to exploit and spoof the local Java service using multiple attack vectors. A successful attack can lead to code executed as SYSTEM by the PingID Windows Login application, or even a denial of service for offline security key authentication. |
| information disclosure due to cryptographic issue in Core during RPMB read request. |
| PingID Desktop prior to 1.7.3 has a misconfiguration in the encryption libraries which can lead to sensitive data exposure. An attacker capable of exploiting this vulnerability may be able to successfully complete an MFA challenge via OTP. |
| A misconfiguration of RSA in PingID Mac Login prior to 1.1 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass. |
| A misconfiguration of RSA in PingID iOS app prior to 1.19 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass when using PingID Windows Login. |
| A misconfiguration of RSA in PingID Android app prior to 1.19 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass when using PingID Windows Login. |
| A misconfiguration of RSA in PingID Windows Login prior to 2.7 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass. |
| A weak robustness vulnerability exists in the AWS Encryption SDKs for Java, Python, C and Javalcript prior to versions 2.0.0. Due to the non-committing property of AES-GCM (and other AEAD ciphers such as AES-GCM-SIV or (X)ChaCha20Poly1305) used by the SDKs to encrypt messages, an attacker can craft a unique cyphertext which will decrypt to multiple different results, and becomes especially relevant in a multi-recipient setting. We recommend users update their SDK to 2.0.0 or later. |
| A too small set of random characters being used for encryption in Nextcloud Server 18.0.4 allowed decryption in shorter time than intended. |
| A cryptographic issue in Nextcloud Server 19.0.1 allowed an attacker to downgrade the encryption scheme and break the integrity of encrypted files. |
| A vulnerability in the installation component of Cisco Hyperflex HX-Series Software could allow an authenticated, local attacker to retrieve the password that was configured at installation on an affected device. The vulnerability exists because sensitive information is stored as clear text. An attacker could exploit this vulnerability by authenticating to an affected device and navigating to the directory that contains sensitive information. A successful exploit could allow the attacker to obtain sensitive information in clear text from the affected device. |
| Due to the use of an insecure RFID technology (MIFARE Classic), ABUS proximity chip keys (RFID tokens) of the ABUS Secvest FUAA50000 wireless alarm system can easily be cloned and used to deactivate the alarm system in an unauthorized way. |
| The Bluetooth BR/EDR specification up to and including version 5.1 permits sufficiently low encryption key length and does not prevent an attacker from influencing the key length negotiation. This allows practical brute-force attacks (aka "KNOB") that can decrypt traffic and inject arbitrary ciphertext without the victim noticing. |
| The ETSI Enterprise Transport Security (ETS, formerly known as eTLS) protocol does not provide per-session forward secrecy. |
| RSA BSAFE Crypto-J versions prior to 6.2.5 are vulnerable to an Information Exposure Through Timing Discrepancy vulnerabilities during DSA key generation. A malicious remote attacker could potentially exploit those vulnerabilities to recover DSA keys. |
| RSA BSAFE Crypto-J versions prior to 6.2.5 are vulnerable to Information Exposure Through Timing Discrepancy vulnerabilities during ECDSA key generation. A malicious remote attacker could potentially exploit those vulnerabilities to recover ECDSA keys. |
| RSA BSAFE Crypto-C Micro Edition versions prior to 4.1.4 and RSA Micro Edition Suite versions prior to 4.4 are vulnerable to an Information Exposure Through Timing Discrepancy. A malicious remote user could potentially exploit this vulnerability to extract information leaving data at risk of exposure. |
| A vulnerability in the SSH key management for the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, remote attacker to connect to the affected system with the privileges of the root user. The vulnerability is due to the presence of a default SSH key pair that is present in all devices. An attacker could exploit this vulnerability by opening an SSH connection via IPv6 to a targeted device using the extracted key materials. An exploit could allow the attacker to access the system with the privileges of the root user. This vulnerability is only exploitable over IPv6; IPv4 is not vulnerable. |
| An issue was discovered on ABUS Secvest FUAA50000 3.01.01 devices. Due to an insufficient implementation of jamming detection, an attacker is able to suppress correctly received RF messages sent between wireless peripheral components, e.g., wireless detectors or remote controls, and the ABUS Secvest alarm central. An attacker is able to perform a "reactive jamming" attack. The reactive jamming simply detects the start of a RF message sent by a component of the ABUS Secvest wireless alarm system, for instance a wireless motion detector (FUBW50000) or a remote control (FUBE50014 or FUBE50015), and overlays it with random data before the original RF message ends. Thereby, the receiver (alarm central) is not able to properly decode the original transmitted signal. This enables an attacker to suppress correctly received RF messages of the wireless alarm system in an unauthorized manner, for instance status messages sent by a detector indicating an intrusion. |
| A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an attacker in a privileged network position which allows eavesdropping the communication between the affected device and the user. The user must invoke a session. Successful exploitation of the vulnerability compromises confidentiality of the data transmitted. |