Search Results (772 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-51726 2026-04-15 8.4 High
CyberGhostVPNSetup.exe (Windows installer) is signed using the weak cryptographic hash algorithm SHA-1, which is vulnerable to collision attacks. This allows a malicious actor to craft a fake installer with a forged SHA-1 certificate that may still be accepted by Windows signature verification mechanisms, particularly on systems without strict SmartScreen or trust policy enforcement. Additionally, the installer lacks High Entropy Address Space Layout Randomization (ASLR), as confirmed by BinSkim (BA2015 rule) and repeated WinDbg analysis. The binary consistently loads into predictable memory ranges, increasing the success rate of memory corruption exploits. These two misconfigurations, when combined, significantly lower the bar for successful supply-chain style attacks or privilege escalation through fake installers.
CVE-2025-14763 1 Amazon 1 Aws S3 Encryption Client Java 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the Amazon S3 Encryption Client for Java may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade Amazon S3 Encryption Client for Java to version 4.0.0 or later.
CVE-2025-14759 1 Amazon 1 Aws S3 Encryption Client Dotnet 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the Amazon S3 Encryption Client for .NET may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade Amazon S3 Encryption Client for .NET to version 3.2.0 or later.
CVE-2023-41927 2026-04-15 5.3 Medium
The server supports at least one cipher suite which is on the NCSC-NL list of cipher suites to be phased out, increasing the risk of cryptographic weaknesses.
CVE-2023-41928 2026-04-15 5.3 Medium
The device is observed to accept deprecated TLS protocols, increasing the risk of cryptographic weaknesses.
CVE-2025-2920 2026-04-15 2 Low
A vulnerability was found in Netis WF-2404 1.1.124EN. It has been rated as problematic. This issue affects some unknown processing of the file /еtc/passwd. The manipulation leads to use of weak hash. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-26708 2026-04-15 4.2 Medium
There is a configuration defect vulnerability in ZTELink 5.4.9 for iOS. This vulnerability is caused by a flaw in the WiFi parameter configuration of the ZTELink. An attacker can obtain unauthorized access to the WiFi service.
CVE-2025-26486 2026-04-15 6 Medium
Broken or Risky Cryptographic Algorithm, Use of Password Hash With Insufficient Computational Effort, Use of Weak Hash, Use of a One-Way Hash with a Predictable Salt vulnerabilities in Beta80 "Life 1st Identity Manager" enable an attacker with access to password hashes to bruteforce user passwords or find a collision to ultimately while attempting to gain access to a target application that uses "Life 1st Identity Manager" as a service for authentication. This issue affects Life 1st: 1.5.2.14234.
CVE-2025-65849 1 Altcha 1 Altcha 2026-04-15 9.1 Critical
A cryptanalytic break in Altcha Proof-of-Work obfuscation mode version 0.8.0 and later allows for remote visitors to recover the Proof-of-Work nonce in constant time via mathematical deduction. NOTE: this is disputed by the Supplier because the product's objective is "to discourage automated scraping / bots, not guarantee resistance to determined attackers." The documentation states “the goal is not to provide a secure cryptographic algorithm but to use a proof-of-work mechanism that allows any capable device to decrypt the hidden data.”
CVE-2024-26317 2026-04-15 6.1 Medium
In illumos illumos-gate 2024-02-15, an error occurs in the elliptic curve point addition algorithm that uses mixed Jacobian-affine coordinates, causing the algorithm to yield a result of POINT_AT_INFINITY when it should not. A man-in-the-middle attacker could use this to interfere with a connection, resulting in an attacked party computing an incorrect shared secret.
CVE-2025-14764 1 Amazon 1 Aws S3 Encryption Client Go 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the Amazon S3 Encryption Client for Go may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade Amazon S3 Encryption Client for Go to version 4.0 or later.
CVE-2025-14761 1 Amazon 1 Aws Sdk Php 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the AWS SDK for PHP may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade AWS SDK for PHP to version 3.368.0 or later
CVE-2025-14760 1 Amazon 1 Aws Sdk Cpp 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the AWS SDK for C++ may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade AWS SDK for C++ to version 1.11.712 or later
CVE-2024-53441 2026-04-15 9.1 Critical
An issue in the index.js decryptCookie function of cookie-encrypter v1.0.1 allows attackers to execute a bit flipping attack.
CVE-2024-53845 1 Espressif 1 Esp-idf 2026-04-15 N/A
ESPTouch is a connection protocol for internet of things devices. In the ESPTouchV2 protocol, while there is an option to use a custom AES key, there is no option to set the IV (Initialization Vector) prior to versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. The IV is set to zero and remains constant throughout the product's lifetime. In AES/CBC mode, if the IV is not properly initialized, the encrypted output becomes deterministic, leading to potential data leakage. To address the aforementioned issues, the application generates a random IV when activating the AES key starting in versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. This IV is then transmitted along with the provision data to the provision device. The provision device has also been equipped with a parser for the AES IV. The upgrade is applicable for all applications and users of ESPTouch v2 component from ESP-IDF. As it is implemented in the ESP Wi-Fi stack, there is no workaround for the user to fix the application layer without upgrading the underlying firmware.
CVE-2025-3200 2026-04-15 9.1 Critical
An unauthenticated remote attacker could exploit the used, insecure TLS 1.0 and TLS 1.1 protocols to intercept and manipulate encrypted communications between the Com-Server and connected systems.
CVE-2025-45764 2026-04-15 3.2 Low
jsrsasign v11.1.0 was discovered to contain weak encryption. NOTE: this issue has been disputed by a third party who believes that CVE IDs can be assigned for key lengths in specific applications that use a library, and should not be assigned to the default key lengths in a library. This dispute is subject to review under CNA rules 4.1.4, 4.1.14, and other rules; the dispute tagging is not meant to recommend an outcome for this CVE Record.
CVE-2025-41223 2026-04-15 4.8 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected devices support the TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256 cipher suite, which uses CBC (Cipher Block Chaining) mode that is known to be vulnerable to timing attacks. This could allow an attacker to compromise the integrity and confidentiality of encrypted communications.
CVE-2024-36440 1 Swissphone 1 Dical-red 2026-04-15 6.8 Medium
An issue was discovered on Swissphone DiCal-RED 4009 devices. An attacker with access to the file /etc/deviceconfig may recover the administrative device password via password-cracking methods, because unsalted MD5 is used.
CVE-2025-6521 2026-04-15 7.6 High
During the initial setup of the device the user connects to an access point broadcast by the Sight Bulb Pro. During the negotiation, AES Encryption keys are passed in cleartext. If captured, an attacker may be able to decrypt communications between the management app and the Sight Bulb Pro which may include sensitive information such as network credentials.