Search Results (179 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-16821 1 Ibm 2 Aix, Powervm Vios 2026-08-28 7 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to a format string vulnerability.
CVE-2026-19437 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-27 8.1 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to execute arbitrary code due to a buffer overflow.
CVE-2026-17145 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-27 9.8 Critical
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to execute arbitrary code due to improper privilege management.
CVE-2026-17124 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-27 7.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to execute arbitrary code due to an out-of-bounds read.
CVE-2026-17006 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-27 8.3 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to execute arbitrary code due to a heap buffer overflow.
CVE-2026-16991 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-27 7.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to improper handling of symbolic links.
CVE-2026-16919 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-27 9.8 Critical
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to execute arbitrary code due to improper validation of network-supplied pointers.
CVE-2026-4932 1 Ibm 35 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 32 more 2026-08-26 4.2 Medium
IBM PowerVM Hypervisor FW1110.00 through FW1110.20, and FW1060.00 through FW1060.71 could allow an attacker with physical access to the Transparent Memory Encryption (TME) hardware to decrypt encrypted memory due to insufficient cryptographic entropy.
CVE-2026-11885 1 Ibm 61 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 58 more 2026-08-26 8.4 High
IBM PowerVM Hypervisor FW1110.00 through FW1110.20, FW1060.00 through FW1060.71, and FW950.00 through FW950.H1 A carefully crafted OS hypervisor call can cause the PowerVM hypervisor to crash or compromise OS memory integrity.
CVE-2026-16838 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-26 7 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to overwrite critical files and obtain sensitive information due to a time-of-check to time-of-use (TOCTOU) race condition.
CVE-2026-16935 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-26 7.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to a time-of-check to time-of-use (TOCTOU) race condition.
CVE-2026-16945 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-26 7.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to execute arbitrary code due to a stack-based buffer overflow.
CVE-2026-19783 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-26 6.7 Medium
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to cause kernel memory corruption due to insufficient validation. A crafted filesystem image can trigger an out-of-bounds kernel-stack write during directory reads, causing a system crash or potentially enabling privilege escalation.
CVE-2026-19449 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-25 8.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 has a vulnerability in cmdnim that may allow an unprivileged local user to executes the payload as root.
CVE-2026-17028 1 Ibm 54 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 51 more 2026-08-25 6.5 Medium
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in partition firmware during network boot. An unauthenticated attacker with access to the same network as a partition undergoing iSCSI SAN network boot can prevent that partition from completing its boot sequence. Other partitions and the managed system are not affected. Only partitions actively performing an iSCSI SAN network boot are affected, resulting in an availability impact.
CVE-2026-17091 1 Ibm 54 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 51 more 2026-08-25 8.4 High
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call to inject an arbitrary amount of data into hypervisor or partition memory, resulting in either a crash causing a full platform re-IPL and terminating all hosted partitions, or corruption of hypervisor or partition memory. The PowerVM hypervisor will restart automatically; however, repeated exploitation could result in a sustained availability impact. Successful exploitation results in an integrity and availability impact to the managed system.
CVE-2026-17097 1 Ibm 54 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 51 more 2026-08-25 7.3 High
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call causing a virtual processor to become permanently unresponsive, requiring a full platform re-IPL to restore normal operation. In some cases this may also cause the guest to inject a small amount of data into hypervisor or partition memory with no attacker control over the target location. Successful exploitation results in an integrity and availability impact to the managed system.
CVE-2026-17414 1 Ibm 54 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 51 more 2026-08-25 8.1 High
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 Power Systems Firmware is affected by a vulnerability in partition firmware during network boot. An unauthenticated attacker with access to the same network as a partition performing a network boot can prevent that partition from completing its boot sequence. On partitions where OS secure boot is not enabled, which is the default configuration, the attacker can also substitute the boot image, compromising everything subsequently loaded by that partition. Other partitions and the managed system are not affected. Only partitions actively performing a network boot are affected, resulting in a confidentiality, integrity, and availability impact.
CVE-2026-18821 1 Ibm 54 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 51 more 2026-08-25 7.5 High
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 Power Systems Firmware is affected by a vulnerability in partition firmware during network boot. An unauthenticated attacker on the same network as a partition undergoing network boot can send a malformed packet, allowing arbitrary code to be executed in the partition firmware and compromising everything subsequently loaded by that partition. Other partitions and the managed system are not affected. Only partitions actively performing a network boot are affected, resulting in a confidentiality, integrity, and availability impact.
CVE-2026-18871 1 Ibm 40 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 37 more 2026-08-25 7.3 High
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in host firmware configuration parsing. An attacker with authenticated service-level access to the service processor can write specially crafted configuration data, causing the host firmware boot stack to crash with possible memory corruption during system initialisation, resulting in an integrity and availability impact to the managed system.